WATER QUALITY INSTRUMENTS


Meters & Testers
Hydrolab Instruments
Underwater Temp. Recorder
Water Quality Sensors
Dissolved Oxygen Probe
Turbidity Sensor
YSI Meters
Test Kits




 

YSI Meters
YSI 30: Conductivity, Salinity and Temperature Meter
YSI 63: pH, Conductivity, Temperature & Salinity Meter
YSI 550: Dissolved Oxygen Meter
YSI 85: Salinity, Conductivity, Dissolved Oxygen & Temperature Meter
YSI 556: Handheld Multi-Probe Meter

YSI 556: Handheld Multi-Probe Meter

The YSI 556 simultaneously measures dissolved oxygen, pH, conductivity, temperature, and ORP. Rugged, reliable and waterproof, the YSI 556 MPS (Multi-Probe System) combines the versatility of an easy-to-use, easy-to-read handheld unit with all the functionality of a multi-parameter system. Featuring an IP-67, impact-resistant case, the YSI 556 MPS assists the user in conforming to GLP standards.

Measurements are easy with field-replaceable DO electrode modules and easy-to-use, screw-on cap DO membranes. Two models are available. The standard model measures dissolved oxygen, pH, conductivity, temperature and ORP. The YSI 556 model with an internal barometer provides barometric pressure measurements in addition to the measurements taken by the standard model.

Features:

  • Field-replaceable DO electrode modules
  • RS232 and compatible with Ecowatch™ for Windows™ data analysis software
  • Easy-to-use, screw-on cap DO membranes
  • 3-year warranty on the instrument, 1-year on the probe module and cables
  • Stores over 49,000 data sets, time and date stamped
  • User upgradeable software from YSI
  • Meets IP-68 water tightness requirements, submersible to 3 feet

Order the instrument, cable and accessories separately.

Measurement Specifications: Dissolved Oxygen - Range: 0 to 500% air saturation/0 to 50 mg/L. Accuracy: 0 to 200% air saturation, ±2% of the reading or 2% air saturation, whichever is greater; 200 to 500% air saturation, ±6% of the reading/0 to 20 mg/L, ±2% of the reading or 0.2 mg/L, whichever is greater; 20 to 50 mg/L, ±6% of the reading. Resolution: 0.1% air saturation/0.01 mg/L. pH-Range:0 to 14. Accuracy: ±0.5% of reading +0.001 mS/cm. Resolution: 0.001 mS/cm to 0.1 mS/cm (range-dependent). Temperature-Range: -5° C to 45° C. Accuracy: ±0.15° C. Resolution: 0.1° C. ORP-Range: -999 to +999 mV. Accuracy: ±20 mV. Resolution: 0.1 mV. Barometer (optional) - Range: 500 to 800 mm Hg. Accuracy:±3 mm Hg within ±15° C temperature range from calibration point. Resolution: 0.1 mm Hg.

704-100 YSI 556 w/ carrying case 2.3 lbs.    
704-110 YSI 556 w/ barometer w/case 2.3 lbs.    
704-111 4 m cable and DO/Temp./Conductivity 3 lbs.    
704-112 10 m cable and DO/Temp./Conductivity 5 lbs.    
704-113 20 m cable and DO/Temp./Conductivity 7 lbs.    
704-115 pH Kit 1 lb.    
704-116 pH/ORP kit  1 lb.    
704-120 Flow chamber 2.5 lbs.    
704-121 Dissolved oxygen membrane kit, 6 ea. w/ electrolyte  0.8 lb.    
704-125 pH 4 buffer (460 ml)  1.2 lbs.    
704-126 pH 7 buffer (460 ml) 1.2 lbs.    
704-127 pH 10 buffer (460 ml) 1.2 lbs.    
704-060 Conductivity Solution, 1,000 µS/cm (460 ml) 1.2 lbs.    
704-061 Conductivity Solution, 10,000 µS/cm (460 ml) 1.2 lbs.    
704-062 Conductivity Solution, 50,000 µS/cm (460 ml) 1.2 lbs.    
704-130 Zobell solution for ORP calibration (125 ml)  0.4 lb.    
704-135  Rechargeable Battery Kit 1.3 lbs.    

 

 

1700 JOYCE AVENUE  COLUMBUS, OH 43219   U.S. Only: 1-800-561-9677   PHONE: 1-614.297.9877  FAX: 1-614.297.9878  sales@rickly.com